Astro-design PORTABLE SIGNAL GENERATOR PROGRAMMING SOFTWARE SP- Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Acessórios para Computador Astro-design PORTABLE SIGNAL GENERATOR PROGRAMMING SOFTWARE SP-. Astro Design PORTABLE SIGNAL GENERATOR PROGRAMMING SOFTWARE SP-8848 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 127
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - SP-8848

Portable signal generator programming software SP-8848 Instruction Manual Ver.2.6

Página 2

(3) On the "Select installation destination" dialog screen, select the directory into which the SP-8848 is to be copied. As the default, t

Página 3

2.15. Creating and editing the DDC data This section describes the program used to set DDC data of the programmable video signal generator (hereaft

Página 4

Chapter 2 Operation 93 No. Item Details ① DispMode selectors These are used to select either the GUI display mode or the binary display mode. ●

Página 5

2.15.3. peration methods Creating new DDC data 1) Click [New] on the [File] menu. The dialog box for selecting the number of blocks (size of the

Página 6

Chapter 2 Operation 95 Sending data to the monitor The DDC data is saved in the monitor ROM. 1) When [Send] on the [VG] menu is selected or the

Página 7

2.15.4. Menus [File] menu Menu command Description of function New This is used to create new data. Open This is used to open a file. Load One-

Página 8 - Forew Word

Chapter 2 Operation 97 [Help] menu Menu command Description of function Contents This displays the help information. Index This displays a list

Página 9 - About the SP-8848

2.16. Cursor tool program This section describes how to move the VG's cursor pattern just as would be done using a mouse and save the coordina

Página 10

Chapter 2 Operation 99 No. Item Details ① Toolbar ● New: Click this to create a new defective pixel list. ● Save: Click this to save the defect

Página 11 - 1.3.3. Uninstallation method

2.16.3. Operation method Startup At startup, the VG model and currently executed resolution are captured, and a screen matching these states is di

Página 12 - 1.3.4. Directories and files

Chapter 2 Operation 101 Saving a defective pixel list in a file  The displayed defective pixel list is saved in a file.  The list is saved in

Página 13 - 1.3.5. Other files

Chapter 1 About the SP-8848 31.3.2. Installing the USB driver (1) When the system is connected with the VG for the first time, it recognizes the VG,

Página 14

2.17. All data copy tool All data of VG can be copied to the same model VG that are connected through LAN communication at once.2.17.1. Startup

Página 15 - Chapter 1 About the SP-8848

Chapter 2 Operation 1032.17.3. OPERATION (1) Before startup 1) Set LAN communication and IP address (VG) in the screen of [Config] in [VG Base]. 2)

Página 16

e.g.) Suppose the data is set as below in [VGBase][Config][Interface] [VG(LAN)]. No. VGName IP address Setting of IP address 1 VG1 192.168

Página 17 - Operation

Chapter 2 Operation 1052.18. ClosedCaption/V-chip data transmission tool * This tool can be used with VG-848,858,849,859,849C,859C. 2.18.1.Sta

Página 18

Caption setting screen No. Item Details ① V-chip setting display This button is used to display the V-chip setting screen. ② CC mode settings

Página 19 - 2.4. Configuration settings

Chapter 2 Operation 107 FontStyle setting screen ⑦ ⑥ ⑤ ④ ③ ② ① FontStyle setting screen No. Item Details This is pressed

Página 20

108 Binary editor Binary data setting screen No. Item Details ① SET button This is pressed to convert the edited binary data into

Página 21

Chapter 2 Operation 109 Text data setting screen ⑨ ⑧ ⑦ ⑥ ⑤ ④ ③ ② ①

Página 22

Text setting screen No. Item Details ① V-chip setting display This button is used to display the V-chip setting screen. ② CC mode settings These

Página 23 - ■ Control page

Chapter 2 Operation 111 V-chip setting screen ⑫ ⑪ ⑩ ⑨ ⑧ ⑦ ⑥ ⑤ ④ ③ ② ①

Página 24 - 2.5.1. Startup method

1.3.4. Directories and files The directory and files listed below are created by the installation of the software. Specified directory (default: C:¥

Página 25

V-chip Setting screen No. Item Details ① CC setting display This is pressed to display the closed caption setting screen. ② Tool buttons ● Loa

Página 26

Chapter 2 Operation 1132.18.3. Operation method ClosedCaption (a) Closed captions Start up the program. The closed caption setting screen is th

Página 28

33 10bit Image data 3.1. 10bit Image data 10bit image data of the yacht barber who shows in the figure below is appended to SP-8848. The resoluti

Página 30 - [Setting the data]

44 Error message reference Error message Code (HEX) Description of error Panel ROM Unsetted 00 The EE-PROM has not been inserted into the panel

Página 31

OPT PTN FAT error 2C Error in user-generated optional pattern FAT. OPT PTN Not Registed 2D No user-generated optional patterns have been regist

Página 32

SP-8848 NOTICE ● An incorrectly collated manual or a manual with missing pages will be replaced. ● All copyrights pertaining to this p

Página 33

Chapter 1 About the SP-8848 5Exe (executable files of SP-8848) (*.exe) ADEdit.exe/CharEdit.exe/CnfgEdit.exe/GrpEdit.exe/LpEdit.exe/OptEdit.exe/PrgEd

Página 34

1.3.6. Registration of Registry The data is registered in the registry as below. HKEY_LOCAL_MACHINE ¥Software¥Astrodesign¥SP8848¥ By starting up

Página 35

Chapter 1 About the SP-8848 7The below screen is shown. (4) By pressing “Repair” button, SP-8848 is re-installed. (5) When

Página 37

22 Operation 2.1. General The basic operations consist of starting up "VGBase," creating and editing data, sending the data to and receiv

Página 38 - Chapter 5 Repeat

(3) The "Layout Info Setting" (layout data setting) dialog box for setting the data at startup appears. If layout data is to be used, sele

Página 39

Chapter 2 Operation 112.3. Closing VGBase Procedure for closing "VGBase" Click the [Close] button. 2.4. Configuration settings Procedu

Página 41

Click [Apply] so that the configuration settings will take effect and the actual changes will be made. When this button is clicked on the [Interfac

Página 42

Chapter 2 Operation 13When VG (Serial) has been selected as the communication method: Port The port number is selected here. [Sense] button This

Página 43

*1: As a general rule, use the default value for the port number. If it cannot be used due to the network connected, change to a different port numb

Página 44 - OPT: Optional pattern

Chapter 2 Operation 15 Control page The display mode settings of the VG can be changed on this page. Display "Direct Display" or "G

Página 45

2.5. Creating and editing the program data This section describes how the VG program data is set. Program data can be created, edited, sent to th

Página 46

Chapter 2 Operation 17Help Help details are displayed by pressing the button. Tool buttons Show Err: When the button is clicked, the error windo

Página 47 - Pull-down scroll

Basic operations ①Loading a file Before creating new data, proceed with "Creating and editing the program data" in (2) on the next page. 1

Página 48

Chapter 2 Operation 19③Saving the file After changing the program data, click the [Save] button or [Save As] button to save the data in the file. 

Página 49 - Character flicker

Timing data setting screen Vertical timing data setting screenHorizontal timing data setting [Setting the data] ● Align the mouse cursor with

Página 50 - ■ Audio data setting screen

Chapter 2 Operation 21Timing data settings [Frequencies] Dot clock frequency 5.000 to 300.000 MHz Horizontal sync frequency 10.000 to 300.000 kHz

Página 51 - ■ HDMI data setting screen

Portable signal generator programming software SP-8848 Instruction Manual 2007.2 Ver.2.6 ASTRODESIGN,Inc

Página 52

Output condition data setting screen Output condition data setting screen [Setting the data] ● Select the applicable radio buttons. ● Where

Página 53

Chapter 2 Operation 23Output condition data settings Mode ANALOG, Tri-Sync (1080) ,Tri-Sync (720) ,NTSC ,PAL ,SECAM is selected here. HS "NEG

Página 54

Pattern data setting screen Buttons for setting therespective patterns Buttons for selectingthe patterns Character patternsettings Selecting

Página 55 - FieldRepeat

Chapter 2 Operation 25Pattern selection CHARA Character CROSS Crosshatch DOTS Dots Circle Center marker Edge marker CIRCLE Diagonal line CURSOR Curs

Página 56 - ■ ACP data setting screen

CROSS: Crosshatch pattern This button is used to set the crosshatch pattern. The crosshatch pattern is always displayed after the screen center ha

Página 57

Chapter 2 Operation 27DOTS: Dot pattern This button is used to set the dot pattern. The dot pattern is always displayed after the screen center ha

Página 58 - ■ CEC data setting screen

CIRCLE: Circle pattern This button is used to set the circle pattern. The number of circles, etc. can be set. Format This is selected

Página 59 - ■ ADF data setting screen

Chapter 2 Operation 29CURSOR: Cursor pattern This button is used to set the cursor pattern. Format The shape of the cursor is select

Página 60

COLOR: Color bar pattern This button is used to set the color bar pattern. The color bar pattern is always drawn in accordance with the interval p

Página 61 - Execute

Chapter 2 Operation 31GRAY: Gray scale pattern This button is used to set the gray scale pattern. When the analog mode or Tri-Sync has been select

Página 63

BURST: Burst pattern This button is used to set the burst pattern. Format The drawing start point is selected here. Step The increme

Página 64

Chapter 2 Operation 33WINDOW: Window pattern This button is used to select the window pattern. When the analog mode or Tri-Sync has been selected

Página 65

WINDOW: Window 4Level Flicker Set the value of Window 4 Level Flicker. Window level can be set 4-level. Each level can output in the setting t

Página 66 - 2.6.1. Startup method

Chapter 2 Operation 35WINDOW: Window 16Level Flicker Set the value of Window 16Level Flicker. Window level can be set 16-level. Each level can

Página 67 - 2.6.3. Operation methods

OPT: Optional pattern This is used to set the optional patterns. When an optional pattern is set, no other patterns can be superimposed onto it.

Página 68

Chapter 2 Operation 37NAME: Program data name This is used to display the name of the program data displayed. A new program data name can be set by

Página 69 - 2.7.1. Startup method

GRAPHIC: Graphic color This is used to set the graphic colors. When the analog mode or Tri-Sync has been selected as the output condition "Mode

Página 70 - 2.7.3. Operation methods

Chapter 2 Operation 39 Action data setting screen Pull-down scroll Action data setting screen Action data setting screen Click the check box to

Página 71

Pattern pull-down scroll setting screen Interval2 The interval from 0 to 999V is set here. Interval3 The interval from 0 to 999V is set here. Int

Página 72 - 2.8.1. Startup method

Chapter 2 Operation 41Setting ranges Action interval Action Interval 1 to 999 V Interval2 0 to 999 V Interval3 0 to 999 V Interval4 0 to

Página 73 - 2.8.3. Operation methods

CCOONNTTEENNTTSS Chapter 1 About the SP-8848 ...

Página 74

Audio data setting screen Frequency settings Level settingsSweep Mode settings Sweep Mode "Sweep OFF," "Frequency," "L

Página 75 - 2.9.1. Startup method

Chapter 2 Operation 43 HDMI data setting screen ※A setting screen is a thing at the time of VG-849 selection. ① ③ ② ⑤ ④ ⑥

Página 76 - 2.9.3. Operation methods

No. Item name Details ① HDMI Mode Set HDMI output mode. Select from OFF, HDMI, HDMI1.1, DVI, or AUTO. ② Video ・Video Fomat Select the video for

Página 77 - 2.10.1. Startup method

Chapter 2 Operation 45 InfoFrame data setting screen ※A setting screen is a thing at the time of VG-849 selection. ② ① ③

Página 78 - ■ Simulation Window

No. Item name Details ① AVI ON/OFF Select ON or OFF of InfoFrameAVI. Type Display the type of InfoFrameAVI. Version Set the version of InfoFrameAV

Página 79 - ・Simulation screen

Chapter 2 Operation 47LevelShift Set the level shift. Set between 0 and 15. Down-mixInhibit Select “Permitted” or “Prohibited” of using DownMix.

Página 80 - 2.10.3. Operation methods

ACP data setting screen ※A setting screen is a thing at the time of VG-849 selection. No. Item name Details ① ACP P

Página 81

Chapter 2 Operation 49Count_U setup. Please make a selection from 0 to 255. Q_A Q_A setup. Please make a selection from 0 or 1. Q_S Q_S setup. Pleas

Página 82

CEC data setting screen ※A setting screen is a thing at the time of VG-849 selection. ① ② ③ ④ No. Item name Details ①

Página 83

Chapter 2 Operation 51 ADF data setting screen ※A setting screen is a thing at the time of VG-849 selection. The "EIA/CEA-861B standard&quo

Página 84 - 2.11.1. Startup method

2.9.2. Window screen and description ...

Página 85 - 2.11.3. Operation methods

ClosedCaption/V-chip data setting screen ClosedCaption V-chip V-chip V-chip data is set up. Please refer to a "2.18. ClosedCaption/V-chip

Página 86 - 2.12.1. Startup method

Chapter 2 Operation 53 Teletext data setting screen Page Execute Line Execute Select ON or OFF for the output Line Set the teletext data transm

Página 87 - ■ Program tab

Page This is used to set the pages for each of the channels. The contents of a page are as being shown below. If a page with any other number is set

Página 88 - ■ Character

Chapter 2 Operation 55 Macrovision data setting screen Macrovision Mode Mode The output mode of a Macrovision is set up. The modes which can be

Página 89 - ■ Group tab

The mode which can be set up for every timing. Timing Mode OFF DVD/STB Type 1 DVD/STB Type 2 DVD/STB Type 3 VHS USA NTSC-M VHS US obs. OFF DVD/STB

Página 90 - ■ AutoDisplay tab

Chapter 2 Operation 57 IA-575 data setting screen Pattern settingTiming setting ScartOutput setting ScartOutput The IA-575 can switch its output

Página 91 - ■ Image tab

2.6. Creating and editing the user characters This section describes how the VG's user characters (hereafter referred to as the "characte

Página 92 - ■ Opt-Ptn tab

Chapter 2 Operation 592.6.3. Operation methods (1)Loading the file Before creating new characters, proceed with "Creating and editing the chara

Página 93 - ■ Sending the data

(5)Sending the characters 1) Click the [Send] button. The "Send to VG" code selection dialog box appears. 2) Set the character code (0xE0

Página 94 - ■ Receiving the data

Chapter 2 Operation 612.7. Creating and editing the group data This section describes how the VG's group data is set. The VG group data can be

Página 95 - 2.13.1. Startup method

2.18. ClosedCaption/V-chip data transmission tool...

Página 96 - 2.13.3. Operation methods

No. Item name Details ① No The number of the group data registered in the VG appears here. ② Neme The name of the group data registered in the VG

Página 97 - 2.14.1. Startup method

Chapter 2 Operation 63(3)Saving the file The displayed data is saved in the file. Click the [Save] button. → The data is saved in the selected file

Página 98 - 2.14.3. Operation methods

2.8. Creating and editing the auto display data This section describes how the VG's auto display data is set. The VG auto display data can be

Página 99 - 2.14.4. Menus

Chapter 2 Operation 652.8.3. Operation methods (1)Loading the file Before creating new auto display data, proceed with "Creating and editing th

Página 100 - 2.15.1. Startup method

(6)Printing the auto display data 1) Click the [Print] button. 2) The "Print" dialog box appears. Set the margins here. 3) Click the [OK

Página 101 - Chapter 2 Operation

Chapter 2 Operation 672.9. Converting the image data This section describes how the VG's image data is set. BMP data or JPG data can be conver

Página 102 - 2.15.3. peration methods

2.9.3. Operation methods (1)Loading the image file BMP files, JPG files and VBM files are loaded and displayed. 1) Click the [Load] button. 2) The &

Página 103 - ■ Printing the DDC data

Chapter 2 Operation 692.10. Creating and editing the optional patterns This section describes how the VG user-created optional patterns (hereafter

Página 104 - 2.15.4. Menus

No. Item name Details ① Code The code registered in the layout data appears here. ② Name The name of the displayed optional pattern appears her

Página 105 - 2.15.5. Block operations

Chapter 2 Operation 71・Simulation screen ⑤ ④ ③ ② ① No. Item Description ① Plane switching Simulated pattern can be disp

Página 106 - 2.16. Cursor tool program

Forew Word Thank you for purchasing the programmable video signal generator. This manual provides details on how to use the SP-8848 software program

Página 107

2.10.3. Operation methods (1)Loading the file Before creating new optional pattern data, proceed with "Creating and editing the optional patter

Página 108 - 2.16.3. Operation method

Chapter 2 Operation 73(6)Printing the optional patterns 1) Click the [Print] button. 2) The "Print" printer setting dialog box appears. Se

Página 109 - 2.16.4. Menus

2.10.4. Convert to 256-color VBM file User option pattern is converted to 256-color VBM file. (1)Write a source code in the edit area. Click [Com

Página 110 - 2.17. All data copy tool

Chapter 2 Operation 75 Caution when making 256-color VBM file The display color of VBM file is 256-color only. When displaying 8-bit plane (25

Página 111 - 2.17.3. OPERATION

2.11. Monitoring and changing the IP/Gateway address This section describes how to monitor the statuses of the VGs which have been connected using

Página 112

Chapter 2 Operation 772.11.3. Operation methods (1)Monitoring The statuses of the connected VGs can be monitored by observing the icon displays at t

Página 113 - 2.18.1.Startup method

2.12. Selecting and editing the layout data files This section explains how to select and edit the layout data files used by "VGBase." 2.

Página 114

Chapter 2 Operation 792.12.2. Window screen and description (Layout Edit) Program tab ⑤ ④ ③ ② ① No. Item Details ① Layo

Página 115

About the data folder The folder of the registered program data is selected. The folder that can be selected by set VG is different. VG folder VG-

Página 116 - ■ Binary editor

Chapter 2 Operation 81 Group tab ④ ③ ② ① No. Item Details ① Layout Name * See same item in program tab section. ② Layout

Página 117 - ■ Text data setting screen

11 About the SP-8848 1.1. General The SP-8848 is an application software program for operating the VG-848, and it is designed to run in a Windows e

Página 118

AutoDisplay tab ④ ③ ② ① No. Item Details ① Layout Name * See same item in program tab section. ② Layout data list * Se

Página 119 - ■ V-chip setting screen

Chapter 2 Operation 83 Image tab ④ ③ ② ① No. Item Details ① Layout Name * See same item in program tab section. ② Layout

Página 120

Opt-Ptn tab ④ ③ ② ① No. Item Details ① Layout Name * See same item in program tab section. ② Layout data list * See sam

Página 121 - ■ EDS(V-chip)

Chapter 2 Operation 852.12.3. Operation methods (Layout Edit) Editing the layout data 1) Click the tab ([AutoDisplay], [Image], [Opt-Ptn], [Progr

Página 122

Receiving the data 1) Click the [Receive] button. The "Transfer Data" data selection dialog box appears. 2) Select the data to be recei

Página 123 - 10bit Image data

Chapter 2 Operation 872.13. Setting the port number and IP address This section describes how to set the port number and IP address for the individ

Página 124

2.13.3. Operation methods Setting the port number and IP addresses 1) Select the serial settings in each of the text boxes under [Serial Setting]

Página 125 - Error message reference

Chapter 2 Operation 892.14. Color difference coefficient data editing program This section describes how to use the editing program to set the colo

Página 126

2.14.3. Operation methods (1)Loading the file The color difference coefficient data is loaded from a file in which it was saved. 1) Click [Open] on

Página 127

Chapter 2 Operation 912.14.4. Menus [File] menu Load This is used to load data from the files. Save This is used to save data in the files. Save

Comentários a estes Manuais

Sem comentários